MiniTest
Medición no destructiva de espesores de capa sobre acero (F), sensores de medición de hasta 15000 µm (F) (sensor externo)
Medición del espesor del revestimiento (digital)

MiniTest 735-F15

Order number: 05252451
Non-Binding Inquiry
With the button below you can add products to your product inquiry list if you want us to do a quote for this product.
Note this product

Medición del espesor del revestimiento (digital)

MiniTest 735-F15

Los medidores de espesores de capa de la serie MiniTest permiten medir de modo no destructivo el espesor de capas no magnéticas (pintura, plástico, cromo y otras capas galvánicas no magnéticas, etc.) sobre substratos ferromagnéticos (acero/hierro) y de capas aislantes (barniz, esmalte, plástico, anodizado, etc.) sobre substratos conductivos (aluminio, cobre, titanio, acero inoxidable austenítico) abarcando, además, muchos rangos de medición.

Norms

  1. DIN EN ISO 1461
  2. DIN EN ISO 2064
  3. DIN EN ISO 2178
  4. DIN EN ISO 2360
  5. DIN EN ISO 2808
  6. DIN EN ISO 3882
  7. DIN EN ISO 19840
  8. ASTM B 244
  9. ASTM B 499
  10. ASTM D7091
  11. ASTM E 376
  12. ASTM AS 3894.3

Technical specifications

Grosor de Capa

up to 15000 µm

DT /NDT

NDT

Humedo/ Seco

dry

Sustrato

F

Dual sensors

Automatic recognition of the substrate material with FN sensors

Data memory

10 batches for a maximum of 10,000 readings (MiniTest 725 and 735)Memories can be partitioned as needed

Statistical evaluation

Number of readings, min, max, mean value, standard deviation, coefficient of variation, single value statistics, blocks statistics (norm-conforming / freely configurable)

Calibration modes

Factory calibration, zero-point-, 2-point-, 3-point-calibration, calibration method “rough“

Calibration procedures according to international standards

ISO, SSPC, “Swedish“, “Australian“

Monitoring of limits

Visual and audible signal output

Measuring units

Switchable from metric (µm, mm, cm) to imperial (mils, inch, thou)

Measuring rate

70 readings per minute in the single mode 20 readings per second in the continuous mode

Continuous mode

For quick identification of thickness variations

Operating temperature

– 10 °C ... 60 °C

Storage temperature

– 20 °C ... 70 °C

Data interfaces

USB and Bluetooth

Power supply

2 pcs batteries, type AA (Mignon); rechargeable NiMH batteries, type AA/HR6 as an option. Battery or rechargeable battery setting option to adapt to the matching nominal voltage

Norms and standards

DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882, 19840, ASTM B 244, B 499, D7091, E 376, AS 3894.3, SS 1841 60, SSPC-PA 2